High quality miniature open style toroidal transformers with two 115V, 50/60Hz primary windings suitable
for connection in series to 230V supply, or parallel to 115V supply.
Click here for 0-115-230V versions (60000 series)
Twin secondary windings may be connected in series or parallel or used independently.
- Very Small size and low weight compared with traditional stacked lamination types.
- Extremely low level of radiated magnetic field
- Very low induced noise (hum)
- Very low iron loss.
- Double insulated primary leads.
- 100% electrical and flash tested
- High quality manufacturing and testing in accordance to EN61558, EN60742, EN60950, EN60065, VDE0551, VDE0550 and
BS415
- Tested and Approved by KEMA to EN61558.
Click here for more info
- UL Recognised to UL506, under family approval file E215495
Important Installation Note
Each transformer is supplied with a resin centre, with through-hole for single bolt fixing.
Under no circumstances should both ends of the fixing bolt contact a metal chassis or frame
as this would create a 'shorted turn' causing irreparable damage.
The following data sheets are available as Adobe Acrobat PDF files.
Series 62000 - Two 115V primary windings for series or parallel connections.
Power VA |
Part No. |
Sec-Full Load Voltage |
Sec Current mA |
Open Circuit Voltage |
1.6
|
62000 62001 62002 62003 62004 62005 |
2x7 2x9 2x12 2x15 2x18 2x22 |
114 89 67 53 44 36 |
2x8.94 2x11.63 2x15.43 2x19.30 2x23.41 2x28.19 |
3.2
|
62010 62011 62012 62013 62014 62015 |
2x7 2x9 2x12 2x15 2x18 2x22 |
229 178 133 107 89 73 |
2x10.2 2x13.0 2x17.3 2x21.4 2x25.7 2x30.5 |
5.0
|
62020 62021 62022 62023 62024 62025 |
2x7 2x9 2x12 2x15 2x18 2x22 |
357 278 208 167 139 114 |
2x9.7 2x12.4 2x17.0 2x21.3 2x25.5 2x30.5 |
7.0
|
62030 62031 62032 62033 62034 62035 |
2x7 2x9 2x12 2x15 2x18 2x22 |
500 389 292 233 194 159 |
2x9.5 2x12.2 2x16.2 2x20.3 2x24.3 2x29.7 |
10.0
|
62040 62041 62042 62043 62044 62015 |
2x7 2x9 2x12 2x15 2x18 2x22 |
714 556 417 333 278 227 |
2x8.3 2x10.8 2x14.4 2x18.0 2x21.7 2x26.3 |
15.0
|
62050 62051 62052 62053 62054 62055 |
2x7 2x9 2x12 2x15 2x18 2x22 |
1071 833 625 500 417 341 |
2x8.9 2x10.8 2x14.4 2x18.0 2x22.2 2x27.2 |
25.0
|
62060 62061 62062 62063 62064 62065 |
2x7 2x9 2x12 2x15 2x18 2x22 |
1785 1377 1041 832 694 568 |
2x8.3 2x10.7 2x14.2 2x17.8 2x21.4 2x26.2 |
35.0
|
62070 62071 62072 62073 62074 62075 |
2x7 2x9 2x12 2x15 2x18 2x22 |
2500 1944 1458 1666 972 795 |
2x8.24 2x10.6 2x14.0 2x17.6 2x20.9 2x25.7 |
50.0
|
62080 62081 62082 62083 62084 62085 |
2x7 2x9 2x12 2x15 2x18 2x22 |
3571 2777 2083 1666 1388 1136 |
2x8.1 2x10.4 2x13.8 2x17.3 2x20.7 2x25.4 |
Mini Toroidal Transformer, Maximum secondary range(*), standard outputs
(Electrical measurements @20 °C ambient temperature)
Power VA |
(*)VA |
(*)Delta Volts(%) |
(*)Delta Temp. °C |
(*)Eff. (%) |
(*)Rec. fuse (mA) |
1.6 3.2 5.0 |
2.0 3.7 5.5 |
60 80 80 |
30 40 40 |
60 50 50 |
32 50 63 |
7.0 10.0 15.0 |
7.5 12.0 16.0 |
70 60 60 |
40 45 40 |
60 60 65 |
80 100 125 |
25.0 35.0 50.0 |
- - - |
- - - |
- - - |
- - - |
- - - |
Mini Toroidal Transformer, Maximum secondary range, standard outputs (Electrical
measurements @20 °C ambient temperature)
Power VA |
Dimensions ODxIDxHT (mm) |
Weight (grams) |
Regulation Delta Volts (%) |
Delta Temp. °C |
Eff. (%) |
No-load (mA) |
230V fuse (mA) |
1.6 3.2 5.0 |
37.5x7.0x17.0 42.0x7.0x17.5 47.0x6.0x18.0 |
71 89 115 |
29 41 45 |
10 20 29 |
77 70 70 |
1.0 1.5 2.0 |
32 32 50 |
|
7.0 10.0 15.0
| 47.0x6.8x21.5 53.5x6.8x23.5 57.5x7.0x24.0 |
145 216 262 |
34 20 23 |
25 24 27 |
74 82 81 |
3.0 3.0 4.0 |
63 80 100 |
25.0 35.0 50.0
| 58.0x13.8x34.5 72.0x17.0x33.5 78.0x22.5x35.0 |
388 453 670 |
19 17.7 15.5 |
28 31 30 |
84 85 86 |
5.0 7.0 8.0 |
160 200 315 |
- Primary-Secondary test voltage 4.0 KV.
- Primaries and secondaries for parallel or series hookup.
- Ambient operating temperature +60 °C
- Maximum.Insulation Class A (105 °C)
- Meets all requirements of Class E(125°C).
|